Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Type of study
Language
Year range
1.
Rev. bras. ortop ; 54(2): 171-177, Mar.-Apr. 2019. tab, graf
Article in English | LILACS | ID: biblio-1013707

ABSTRACT

Abstract Objective To evaluate the classification proposed by David Dejour to describe trochlear dysplasia of the knee through inter- and intraobserver reproducibility measurements. Methods Ten patients with trochlear dysplasia were studied. Three physicians, members of the Sociedade Brasileira de Cirurgia do Joelho (Brazilian Society of Knee Surgery), were invited to evaluate the images. Intra- and interobserver analyses were performed at one-week intervals. Reproducibility was evaluated in four scenarios: using only radiography; using radiography and tomography; using radiography and consulting the classification; and using radiography and tomography, consulting the classification. Results The intraobserver evaluation presented discordant results. In the interobserver analysis, the degree of agreement was low for the analyses that used only radiography and excellent for those in which both radiography and tomography were used. Conclusion The Dejour classification presented a low intra- and interobserver reproducibilitywhenonly the profile radiography was used. It was demonstrated that the use of the radiography alone for classificationmay generate lack of uniformity even among experienced observers. However, when radiography and tomography were combined, reproducibility improved.


Resumo Objetivo Avaliar, pela reprodutibilidade interobservador e intraobservador, a classificação proposta por David Dejour para descrever a displasia troclear do joelho. Métodos Foram estudados dez pacientes com diagnóstico de displasia troclear. Três médicos membros da Sociedade Brasileira de Cirurgia do Joelho foram convidados para avaliar as imagens. Análises intra- e interobservador foram feitas com intervalo de uma semana. A reprodutibilidade foi avaliada em quatro cenários: uso de radiografia; uso de radiografia e tomografia; uso de radiografia, consultando-se a classificação no momento; e uso de radiografia e tomografia, consultando-se a classificação no momento. Resultados A avaliação intraobservador apresentou resultados discordantes. Na análise interobservador, o grau de concordância foi baixo para as análises que usavam apenas a radiografia e excelente para aquelas que associavamradiografia e tomografia. Conclusão A classificação de Dejour apresentou uma baixa reprodutibilidade intra e interobservador quando usada somente a radiografia em perfil. Demonstrou-se que o uso apenas da radiografia para classificar pode gerar falta de uniformidade até mesmo entre observadores experientes. Contudo, quando radiografia e tomografia foram associadas, a reprodutibilidade melhorou.


Subject(s)
Humans , Male , Female , Reproducibility of Results , Patellofemoral Joint , Joint Instability
2.
Arq. bras. cardiol ; 103(5): 375-381, 11/2014. tab
Article in English | LILACS | ID: lil-730360

ABSTRACT

Background: Appropriateness Criteria for nuclear imaging exams were created by American College of Cardiology (ACC) e American Society of Nuclear Cardiology (ASNC) to allow the rational use of tests. Little is known whether these criteria have been followed in clinical practice. Objective: To evaluate whether the medical applications of myocardial perfusion scintigraphy (MPS) in a private nuclear medicine service of a tertiary cardiology hospital were suitable to the criteria of indications proposed by the American medical societies in 2005 and 2009 and compare the level of indication of both. Methods: We included records of 383 patients that underwent MPS, November 2008 up to February 2009. Demographic characteristics, patient's origin, coronary risk factors, time of medical graduation and appropriateness criteria of medical applications were studied. The criteria were evaluated by two independent physicians and, in doubtful cases, defined by a medical expert in MPS. Results: Mean age was 65 ± 12 years. Of the 367 records reviewed, 236 (64.3%) studies were performed in men and 75 (20.4%) were internee. To ACC 2005, 255 (69.5%) were considered appropriate indication and 13 (3.5%) inappropriate. With ACC 2009, 249 (67.8%) were considered appropriate indications and 13 (5.2%) inappropriate. Conclusions: We observed a high rate of adequacy of medical indications for MPS. Compared to the 2005 version, 2009 did not change the results. .


Fundamento: Os critérios de adequação para os exames de imagem nuclear foram criados pelo American College of Cardiology (ACC) e pela American Society of Nuclear Cardiology (ASNC) com o objetivo de permitir o uso racional dos exames. Pouco se sabe se esses critérios têm sido seguidos nas indicações da prática clínica. Objetivo: Avaliar se os pedidos médicos de cintilografia de perfusão miocárdica (CPM), em serviço privado de medicina nuclear de um hospital cardiológico terciário, adequavam-se aos critérios de indicações propostos pelas sociedades médicas americanas em 2005 e 2009 e comparar o grau de indicação entre ambos. Métodos: Foram incluídos 383 prontuários de pacientes submetidos à CPM de novembro de 2008 a fevereiro de 2009. As características demográficas, a origem do paciente, os fatores de risco coronariano, o tempo de formatura do médico e os critérios de adequação dos pedidos foram considerados. Os critérios foram avaliados por dois médicos independentes e, nos casos duvidosos, definidos por um especialista em CPM. Resultados: A média de idade foi de 65 ± 12 anos. Dos 367 prontuários analisados, 236 (64,3%) exames foram realizados em homens e 75 (20,4%) foram em pacientes internados. Aplicando-se os critérios do ACC de 2005, 255 (69,5%) das indicações foram consideradas adequadas e 13 (3,5%) inadequadas. Aplicando-se os critérios do ACC de 2009, 249 (67,8%) das indicações foram consideradas adequadas e 13 (5,2%) inadequadas. Conclusões: Foi observada uma elevada taxa de adequação das indicações médicas de CPM. Comparada com a edição de 2005, a versão de 2009 não alterou a taxa de exames adequados ou inadequados. .